Fire Alarm Posts from Century Electronic Security

Home  |   Contact  |   Site Map

Showing posts tagged with: Fire Alarm

Security System Takeovers

Comments (0) Posted by: Century on July 15th, 2014 @ 3:11 PM
Tagged with: Access Control Access Control Intercom CCTV System Fire Alarm Fire Alarm System Intruder Alarm Systems maintenance monitoring system takeovers

Are you left confused or unhappy after your security system has been serviced?

Do you feel you are not getting your monies worth?

Are you paying too much?

Do you want a faster engineer response?


At Century Electronic Security Ltd, we can take-over the maintenance and monitoring of any Fire & Security System which has been installed or maintained by any other Security Company.

We understand that you have your own requirements and relevant regulations and we can design and implement a service and maintenance package in accordance to these.

Why should you switch to us

At Century Electronic Security we regularly receive calls from customers who ask us if we will take over their existing Security System. Here are a few reasons why people decide to transfer their system maintenance over to us;

  • Their existing company or installer is impossible to get ahold of when needed
  • They have received a poor level of service from their existing installer
  • The current installer or company cannot repair a fault or solve a problem correctly or efficiently
  • They have just moved into a new property, but don't have any details of the system
  • The existing company or installer has gone out of business
  • They are after a professional, well trained company

The systems we take-over

Intruder Alarms, Fire Alarms, CCTV Systems, Access Control, Intercoms, Automatic Gates and Parking Barriers

How do you start the take-over process?

Simply give Century Electronic Security a call or contact us online to enquire about taking over your already existing alarm system.

We will then provide you with a free, no obligation review of your system and a quotation to fix any present faults and take over the service, maintenance and monitoring.

Should you require any new equipment, we are here to advise on the best solution to ensure your home or business is fully covered

 

Conventional Vs. Addressable Fire Alarm Systems: The Differences

Comments (0) Posted by: Century on February 7th, 2014 @ 3:17 PM
Tagged with: Addressable Addressable Fire Alarm System Addressable System Conventional Conventional Fire Alarm System Conventional System Fire Alarm Fire Alarm System Fire Security maintenance Safety Security

 

 Firstly, what is a Conventional Fire Alarm System?

It’s the most common type of system and is suitable for most small businesses such as shops, offices and warehouses. A number of call points and/or detectors are wired to the fire alarm control panel in zones. This is because if a detector detects smoke or fire, it can give you a rough idea as to where it is within the building. For example “smoke detector in alarm in the office lobby”. The accuracy of knowing where a fire has started is controlled by the number of zones the control panel has.

And what’s an Addressable Fire Alarm System?

Although very similar to a Conventional Fire Alarm system in that they both have detection zones, they have the added benefit of having sounders. Because additional sounder circuits are not required, the installation and cost is massively reduced. The detection circuit is wired as a loop and up to 99 devices may be connected to each individual loop. They are essentially Conventional Systems, but with an address built in. The address within each detector is set by a Dual-in-Line switch (DIL) and the control panel is programmed to display the information required when that particular detector is operated.

So what are the main differences?

  • A Conventional Fire Alarm System is typically used in smaller businesses and properties (as stated above). They are usually less expensive than an Addressable System, but with this, they have limitations regarding reporting the exact location of the devices. For example they will display which zone is in alarm, but not which device (which can be a time waste if you have several devices within a large room).  
  • An Addressable Fire Alarm System can be programmed to show the exact device that is in alarm by a display on the panel. For example, the display may show “smoke detector in alarm on second floor outside room 4”. Because an Addressable System is so exact, it is a vital system to have installed on a larger business property as a time-saver (and potentially a life-saver) if there are any alarms.  
  • Addressable Systems can also give detailed information about individual detectors and also allow a courtesy text label to allow easy identification. For example detectors can be labelled after rooms such as “office lobby” or “office filing room”.  
  • Conventional Systems only give information about specific circuits or zones and can’t be labelled. 
  • Addressable Systems are wired in a ‘loop’.  
  • Conventional Systems are normally wired as radial circuits (only usable where each circuit connects to just one high power appliance). 
  • Most Addressable Systems allow for a ‘pre-alarm’ warning, which allows the responsible person to investigate a potential alarm before the system activates its sirens.

 For more information please do not hesitate to contact us on 0800 052 6070.

 

Why Choose Century?

  • We operate 24/7, 365 days a year
  • Comprehensive customer care
  • Highly trained engineers
  • Well established reputation
  • Using State of the art technology
  • Members of the SSAIB
  • Highly experienced consultants
  • Provide FREE site quotes
  • Fast responsive service
  • Speak to a representative not a robot
  • Installations meet with the latest British & European standards.

24/7/365
Emergency
Callout

0800 052 6070